Uplift Troubleshooting Guide

🛠️ Leander Uplift System Troubleshooting Guide

Applies to motorized Leander tables with elevation (uplift) function


1. Does the table have power?

  • Check: Power cord is plugged in securely
  • Confirm: Wall outlet is functional
  • Inspect: Any visible blown fuses or tripped breakers
  • Indicator: If there’s no motor hum or click, it may be a power issue

2. Motor hums but the table doesn’t lift

  • Most likely cause: Failed uplift capacitor
  • Solution: Replace the 110V capacitor mounted to the base frame
  • Other possibilities: Binding in the column or motor gearbox

3. No response from the foot pedal

  • Check: Pedal connection is secure
  • Try: Bypassing the pedal temporarily if possible
  • Inspect: Pedal cable for fraying or wear
  • Test: Swap pedals if you have a spare to rule it out

4. Motor tries to lift but stalls or lifts unevenly

  • Check: Load is within weight capacity
  • Inspect: Base frame bolts for tightness
  • Possible cause: Mechanical binding or failing uplift motor

5. Table lifts slowly or intermittently

  • Check: For visible debris or damage around the lift post
  • Inspect: Isolators or mounting hardware for damage
  • Verify: Capacitor isn’t bulging or leaking

📞 Still stuck?

Contact Leander support with the following info:

  • Table model and serial number
  • Description of symptoms
  • Photos or video, if available

We’re happy to help you identify the issue and get the right part out to you quickly.